Audi and the television acceleration test

Audi 5000: the altered television car and the shift-lock record

By Phil Springer, Editor · Published · Updated · Car Debunk

Audi 5000: the altered television car and the shift-lock record

The Audi 5000 demonstration broadcast by 60 Minutes on 23 November 1986 depended on equipment added to the car. NHTSA's published description identifies a hole drilled into the transmission and compressed air injected through it at the flip of a switch. Pressurizing the transmission made its linkage open the throttle. The accelerator could then move toward the floor without a driver's foot pushing it. The switch remained outside the camera's view during the segment, titled Out of Control. The movement on screen therefore had an identifiable mechanical cause in the modified vehicle.

That description comes from NHTSA's 2000 analysis of a petition to reopen its sudden-acceleration research. The agency said the modified Audi 5000 had been demonstrated to its investigators months before the broadcast. It also stated that it had found no production vehicle configured that way. The demonstration established what this added equipment could make the car do. It did not reproduce an identified configuration in an ordinary production car. The agency's description separates the drilled transmission and external pressure source from the equipment fitted by the manufacturer.

The real cars nevertheless had problems requiring investigation. The National Research Council's 2012 review describes an electronically controlled idle stabilizer fitted to some Audi 5000 versions. Its control unit and electromechanical air valve could malfunction intermittently, producing unusually high idle speeds and engine surging. The investigators considered that these intermittent faults might escape normal testing or inspection after a crash. They distinguished those surges from the sustained high-power acceleration described in complaints. They also considered whether a surge could startle a driver into pressing the accelerator while intending to brake. The control unit selected idle speed using signals including engine speed, coolant temperature, throttle position, and air-conditioner operation.

The same review describes differences between the Audi's pedal and seating layout and those of domestic comparison vehicles. Investigators considered unfamiliarity with those arrangements another possible contributor to pedal errors. They could not identify a combination of faults that would produce both the reported high-power acceleration and complete brake failure, then leave no physical evidence. These were findings about possible mechanisms and the available evidence. The idle-control defect was real; the proposed chain from a startling surge to a mistaken pedal application remained an explanation advanced by investigators.

NHTSA's later technical summary defines the sudden-acceleration pattern narrowly: unexpected high-power acceleration from rest or very low speed, accompanied by an apparent loss of braking. Its 1989 study examined potential vehicle causes and design features that might contribute to pedal errors. In the absence of evidence of a throttle, cruise-control, or brake malfunction, the study attributed the unexplained incidents to inadvertent accelerator application. This conditional conclusion differs from a claim that vehicles cannot suffer faults that hold a throttle open. The agency's 2015 review explicitly separates the low-speed pattern from stuck-throttle events that can begin at higher road speeds.

The response to the Audi 5000 included changing the sequence required to begin driving. Wolfgang Reinhart's original NHTSA conference paper, presented in 1994, records that Audi began retrofitting shift locks in August 1986 for 1984–1986 cars. In January 1987, the work became a formal recall covering the investigated 1978–1986 model years. The lock prevented movement out of Park unless the brake pedal was depressed at the same time. Its purpose was to establish brake application before the driver selected a driving gear. This retrofit began before the television broadcast. Audi's 1987 models also carried factory-installed shift locks.

Reinhart also describes a December 1987 questionnaire sent to approximately 100,000 Audi owners. Investigators compared reported accident dates with the dates individual cars received their shift locks. Cars without the device had an average reported accident rate 2.8 times that of equipped cars. The paper acknowledged that recalls addressing erratic idle complicated the comparison. It noted, however, that the reported decline had begun before those idle-control repairs were widely performed. The figures concern reported incidents and a retrofit comparison; they are not a count of crashes individually reconstructed under controlled conditions.

The interlock also had a defined limit. NHTSA's 2015 review says brake-to-shift devices address errors around departure from Park and do not prevent pedal errors later in a journey, including parking. It separately describes how an entrapped accelerator at road speed can involve prolonged maximum engine power, loss of brake assistance if the reserve vacuum is exhausted, and heat-related brake fade. Those conditions differ from a brief low-speed event with no lasting evidence of brake damage. The Audi 5000 controversy consequently involved several distinct mechanisms: an externally pressurized television car, intermittent idle faults in production cars, pedal application, and a shift-lock remedy directed at the start of driving.

The Question

Which part of the televised car did a consultant drill to connect compressed air?

Show the answer

The Answer

The televised car had been modified to make its throttle open. A consultant drilled a hidden hole in the transmission and connected compressed air, while the segment left the modification undisclosed.

Send this question to a friend

Read next

By clicking “Send me the real story” you agree to Car Debunk’s Terms of Use and Privacy Policy.